﻿<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Overcenter Valve &#8211; Ziyacorp</title>
	<atom:link href="https://ziyacorp.com/product-category/inline-valves/overcenter-valve/feed/" rel="self" type="application/rss+xml" />
	<link>https://ziyacorp.com</link>
	<description>Ziya Corp</description>
	<lastBuildDate>Thu, 30 Jun 2022 06:49:37 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.8</generator>
	<item>
		<title>Double overcenter valve, VBCD DE A CC , 60 L/min, G 1/2&#8243; , VBCD 1/2 DE A CC V0423</title>
		<link>https://ziyacorp.com/product/double-overcenter-valve-vbcd-de-a-cc-60-l-min-g-1-2-vbcd-1-2-de-a-cc-v0423/</link>
					<comments>https://ziyacorp.com/product/double-overcenter-valve-vbcd-de-a-cc-60-l-min-g-1-2-vbcd-1-2-de-a-cc-v0423/#respond</comments>
		
		<dc:creator><![CDATA[theplanmaster]]></dc:creator>
		<pubDate>Thu, 30 Jun 2022 06:49:37 +0000</pubDate>
				<guid isPermaLink="false">https://ziyacorp.com/product/double-overcenter-valve-vbcd-de-a-cc-60-l-min-g-1-2-vbcd-1-2-de-a-cc-v0423/</guid>

					<description><![CDATA[Overcenter valves are used where there is vital importance in the system. VBCD DE A CC series are ideal when other models can not operate properly. If the control valve is closed center, this valve will be a good choice. <div class="vc_row wpb_row row"><div class="vc_column_container col-md-12"><div class="wpb_wrapper vc_column-inner"><div class="vc_btn3-container vc_btn3-inline"><a class="vc_general vc_btn3 vc_btn3-size-md vc_btn3-shape-rounded vc_btn3-style-outline wpb_custom_4eba9bcc8f6c36e45e1d476fc3d9024c vc_btn3-icon-left vc_btn3-color-warning btn" href="https://ziyacorp.com/ziyacorpimages/inline-valves/overcenter-valve/o-vbcd-1-2-de-a-cc/vbcd-de-a-cc.pdf"><i class="vc_btn3-icon far fa-file-pdf"></i> Click for product document</a></div></div></div></div>]]></description>
										<content:encoded><![CDATA[<p>DOUBLE OVERCENTER VALVE FOR CLOSED CENTER<br />VBCD 1/2 DE A CC &#8211; V0423<br />Overcenter valves have great importance in hydraulic systems and have following features:<br />Load holding: The overcenter valve prevents the movement of a load when the directional valve is in the neutral position, permitting the use of open center directional valves and negating leakage past the spool of closed center directional valves.<br />Load holding:<br />Load control: The overcenter valve prevents the actuator running ahead of the pump due to the load-induced energy, thereby eliminating cavitation in the actuator and loss of control.<br />Load control:<br />Load safety: In the case of hose failure, an overcenter valve mounted onto or into a cylinder will prevent uncontrolled movement of the load. When a cylinder is used in a boom, as in a crane, then hose failure protection is vital as the loss of load control could cause damage to people or property.<br />Load safety:<br />These valves are used where there is vital importance in the system.<br />VBCD DE A CC series are ideal when other models can not operate properly. If the control valve is closed center, this valve will be a good choice.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://ziyacorp.com/product/double-overcenter-valve-vbcd-de-a-cc-60-l-min-g-1-2-vbcd-1-2-de-a-cc-v0423/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Double overcenter valve, VBCD DE A CC , 40 L/min, G 3/8&#8243; , VBCD 3/8 DE A CC V0421</title>
		<link>https://ziyacorp.com/product/double-overcenter-valve-vbcd-de-a-cc-40-l-min-g-3-8-vbcd-3-8-de-a-cc-v0421/</link>
					<comments>https://ziyacorp.com/product/double-overcenter-valve-vbcd-de-a-cc-40-l-min-g-3-8-vbcd-3-8-de-a-cc-v0421/#respond</comments>
		
		<dc:creator><![CDATA[theplanmaster]]></dc:creator>
		<pubDate>Thu, 30 Jun 2022 06:49:35 +0000</pubDate>
				<guid isPermaLink="false">https://ziyacorp.com/product/double-overcenter-valve-vbcd-de-a-cc-40-l-min-g-3-8-vbcd-3-8-de-a-cc-v0421/</guid>

					<description><![CDATA[Overcenter valves are used where there is vital importance in the system. VBCD DE A CC series are ideal when other models can not operate properly. If the control valve is closed center, this valve will be a good choice. <div class="vc_row wpb_row row"><div class="vc_column_container col-md-12"><div class="wpb_wrapper vc_column-inner"><div class="vc_btn3-container vc_btn3-inline"><a class="vc_general vc_btn3 vc_btn3-size-md vc_btn3-shape-rounded vc_btn3-style-outline wpb_custom_4eba9bcc8f6c36e45e1d476fc3d9024c vc_btn3-icon-left vc_btn3-color-warning btn" href="https://ziyacorp.com/ziyacorpimages/inline-valves/overcenter-valve/o-vbcd-3-8-de-a-cc/vbcd-de-a-cc.pdf"><i class="vc_btn3-icon far fa-file-pdf"></i> Click for product document</a></div></div></div></div>]]></description>
										<content:encoded><![CDATA[<p>DOUBLE OVERCENTER VALVE FOR CLOSED CENTER<br />VBCD 3/8 DE A CC &#8211; V0421<br />Overcenter valves have great importance in hydraulic systems and have following features:<br />Load holding: The overcenter valve prevents the movement of a load when the directional valve is in the neutral position, permitting the use of open center directional valves and negating leakage past the spool of closed center directional valves.<br />Load holding:<br />Load control: The overcenter valve prevents the actuator running ahead of the pump due to the load-induced energy, thereby eliminating cavitation in the actuator and loss of control.<br />Load control:<br />Load safety: In the case of hose failure, an overcenter valve mounted onto or into a cylinder will prevent uncontrolled movement of the load. When a cylinder is used in a boom, as in a crane, then hose failure protection is vital as the loss of load control could cause damage to people or property.<br />Load safety:<br />These valves are used where there is vital importance in the system.<br />VBCD DE A CC series are ideal when other models can not operate properly. If the control valve is closed center, this valve will be a good choice.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://ziyacorp.com/product/double-overcenter-valve-vbcd-de-a-cc-40-l-min-g-3-8-vbcd-3-8-de-a-cc-v0421/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Double overcenter valve, VBCD DE A CC , 20 L/min, G 1/4&#8243; , VBCD 1/4 DE A CC V0389</title>
		<link>https://ziyacorp.com/product/double-overcenter-valve-vbcd-de-a-cc-20-l-min-g-1-4-vbcd-1-4-de-a-cc-v0389/</link>
					<comments>https://ziyacorp.com/product/double-overcenter-valve-vbcd-de-a-cc-20-l-min-g-1-4-vbcd-1-4-de-a-cc-v0389/#respond</comments>
		
		<dc:creator><![CDATA[theplanmaster]]></dc:creator>
		<pubDate>Thu, 30 Jun 2022 06:49:35 +0000</pubDate>
				<guid isPermaLink="false">https://ziyacorp.com/product/double-overcenter-valve-vbcd-de-a-cc-20-l-min-g-1-4-vbcd-1-4-de-a-cc-v0389/</guid>

					<description><![CDATA[Overcenter valves are used where there is vital importance in the system. VBCD DE A CC series are ideal when other models can not operate properly. If the control valve is closed center, this valve will be a good choice. <div class="vc_row wpb_row row"><div class="vc_column_container col-md-12"><div class="wpb_wrapper vc_column-inner"><div class="vc_btn3-container vc_btn3-inline"><a class="vc_general vc_btn3 vc_btn3-size-md vc_btn3-shape-rounded vc_btn3-style-outline wpb_custom_4eba9bcc8f6c36e45e1d476fc3d9024c vc_btn3-icon-left vc_btn3-color-warning btn" href="https://ziyacorp.com/ziyacorpimages/inline-valves/overcenter-valve/o-vbcd-1-4-de-a-cc/vbcd-de-a-cc.pdf"><i class="vc_btn3-icon far fa-file-pdf"></i> Click for product document</a></div></div></div></div>]]></description>
										<content:encoded><![CDATA[<p>DOUBLE OVERCENTER VALVE FOR CLOSED CENTER<br />VBCD 1/4 DE A CC &#8211; V0389<br />Overcenter valves have great importance in hydraulic systems and have following features:<br />Load holding: The overcenter valve prevents the movement of a load when the directional valve is in the neutral position, permitting the use of open center directional valves and negating leakage past the spool of closed center directional valves.<br />Load holding:<br />Load control: The overcenter valve prevents the actuator running ahead of the pump due to the load-induced energy, thereby eliminating cavitation in the actuator and loss of control.<br />Load control:<br />Load safety: In the case of hose failure, an overcenter valve mounted onto or into a cylinder will prevent uncontrolled movement of the load. When a cylinder is used in a boom, as in a crane, then hose failure protection is vital as the loss of load control could cause damage to people or property.<br />Load safety:<br />These valves are used where there is vital importance in the system.<br />VBCD DE A CC series are ideal when other models can not operate properly. If the control valve is closed center, this valve will be a good choice.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://ziyacorp.com/product/double-overcenter-valve-vbcd-de-a-cc-20-l-min-g-1-4-vbcd-1-4-de-a-cc-v0389/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Double overcenter valve, VBCD DE A FLV , 40 L/min, G 3/8&#8243; , VBCD 3/8 DE A FLV V0422/FLV</title>
		<link>https://ziyacorp.com/product/double-overcenter-valve-vbcd-de-a-flv-40-l-min-g-3-8-vbcd-3-8-de-a-flv-v0422-flv/</link>
					<comments>https://ziyacorp.com/product/double-overcenter-valve-vbcd-de-a-flv-40-l-min-g-3-8-vbcd-3-8-de-a-flv-v0422-flv/#respond</comments>
		
		<dc:creator><![CDATA[theplanmaster]]></dc:creator>
		<pubDate>Thu, 30 Jun 2022 06:49:34 +0000</pubDate>
				<guid isPermaLink="false">https://ziyacorp.com/product/double-overcenter-valve-vbcd-de-a-flv-40-l-min-g-3-8-vbcd-3-8-de-a-flv-v0422-flv/</guid>

					<description><![CDATA[Overcenter valves are used where there is vital importance in the system. VBCD DE A FLV series are used to control actuator’s movement and block in both directions. Pressure is adjustable and sensitive. They can be used on crane booms and can easily mounted on cylinder with special screw. <div class="vc_row wpb_row row"><div class="vc_column_container col-md-12"><div class="wpb_wrapper vc_column-inner"><div class="vc_btn3-container vc_btn3-inline"><a class="vc_general vc_btn3 vc_btn3-size-md vc_btn3-shape-rounded vc_btn3-style-outline wpb_custom_4eba9bcc8f6c36e45e1d476fc3d9024c vc_btn3-icon-left vc_btn3-color-warning btn" href="https://ziyacorp.com/ziyacorpimages/inline-valves/overcenter-valve/o-vbcd-3-8-de-a-flv/vbcd-de-a-flv.pdf"><i class="vc_btn3-icon far fa-file-pdf"></i> Click for product document</a></div></div></div></div>]]></description>
										<content:encoded><![CDATA[<p>DOUBLE OVERCENTER VALVE<br />VBCD 3/8 DE A FLV &#8211; V0422/FLV<br />Overcenter valves have great importance in hydraulic systems and have following features:<br />Load holding: The overcenter valve prevents the movement of a load when the directional valve is in the neutral position, permitting the use of open center directional valves and negating leakage past the spool of closed center directional valves.<br />Load holding:<br />Load control: The overcenter valve prevents the actuator running ahead of the pump due to the load-induced energy, thereby eliminating cavitation in the actuator and loss of control.<br />Load control:<br />Load safety: In the case of hose failure, an overcenter valve mounted onto or into a cylinder will prevent uncontrolled movement of the load. When a cylinder is used in a boom, as in a crane, then hose failure protection is vital as the loss of load control could cause damage to people or property.<br />Load safety:<br />These valves are used where there is vital importance in the system.<br />VBCD DE A FLV series overcenter valves are used to control actuator’s movement and block in both directions. Pressure is adjustable and sensitive. They can be used on crane booms. Standard pressure setting is 320 bar.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://ziyacorp.com/product/double-overcenter-valve-vbcd-de-a-flv-40-l-min-g-3-8-vbcd-3-8-de-a-flv-v0422-flv/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Double overcenter valve, VBCD DE A FLV , 60 L/min, G 1/2&#8243; , VBCD 1/2 DE A FLV V0432/FLV</title>
		<link>https://ziyacorp.com/product/double-overcenter-valve-vbcd-de-a-flv-60-l-min-g-1-2-vbcd-1-2-de-a-flv-v0432-flv/</link>
					<comments>https://ziyacorp.com/product/double-overcenter-valve-vbcd-de-a-flv-60-l-min-g-1-2-vbcd-1-2-de-a-flv-v0432-flv/#respond</comments>
		
		<dc:creator><![CDATA[theplanmaster]]></dc:creator>
		<pubDate>Thu, 30 Jun 2022 06:49:34 +0000</pubDate>
				<guid isPermaLink="false">https://ziyacorp.com/product/double-overcenter-valve-vbcd-de-a-flv-60-l-min-g-1-2-vbcd-1-2-de-a-flv-v0432-flv/</guid>

					<description><![CDATA[Overcenter valves are used where there is vital importance in the system. VBCD DE A FLV series are used to control actuator’s movement and block in both directions. Pressure is adjustable and sensitive. They can be used on crane booms and can easily mounted on cylinder with special screw. <div class="vc_row wpb_row row"><div class="vc_column_container col-md-12"><div class="wpb_wrapper vc_column-inner"><div class="vc_btn3-container vc_btn3-inline"><a class="vc_general vc_btn3 vc_btn3-size-md vc_btn3-shape-rounded vc_btn3-style-outline wpb_custom_4eba9bcc8f6c36e45e1d476fc3d9024c vc_btn3-icon-left vc_btn3-color-warning btn" href="https://ziyacorp.com/ziyacorpimages/inline-valves/overcenter-valve/o-vbcd-1-2-de-a-flv/vbcd-de-a-flv.pdf"><i class="vc_btn3-icon far fa-file-pdf"></i> Click for product document</a></div></div></div></div>]]></description>
										<content:encoded><![CDATA[<p>DOUBLE OVERCENTER VALVE<br />VBCD 1/2 DE A FLV &#8211; V0432/FLV<br />Overcenter valves have great importance in hydraulic systems and have following features:<br />Load holding: The overcenter valve prevents the movement of a load when the directional valve is in the neutral position, permitting the use of open center directional valves and negating leakage past the spool of closed center directional valves.<br />Load holding:<br />Load control: The overcenter valve prevents the actuator running ahead of the pump due to the load-induced energy, thereby eliminating cavitation in the actuator and loss of control.<br />Load control:<br />Load safety: In the case of hose failure, an overcenter valve mounted onto or into a cylinder will prevent uncontrolled movement of the load. When a cylinder is used in a boom, as in a crane, then hose failure protection is vital as the loss of load control could cause damage to people or property.<br />Load safety:<br />These valves are used where there is vital importance in the system.<br />VBCD DE A FLV series overcenter valves are used to control actuator’s movement and block in both directions. Pressure is adjustable and sensitive. They can be used on crane booms. Standard pressure setting is 320 bar.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://ziyacorp.com/product/double-overcenter-valve-vbcd-de-a-flv-60-l-min-g-1-2-vbcd-1-2-de-a-flv-v0432-flv/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Double overcenter valve, VBCD DE FL , 60 L/min, G 1/2&#8243; , VBCD 1/2 DE FL V0434</title>
		<link>https://ziyacorp.com/product/double-overcenter-valve-vbcd-de-fl-60-l-min-g-1-2-vbcd-1-2-de-fl-v0434/</link>
					<comments>https://ziyacorp.com/product/double-overcenter-valve-vbcd-de-fl-60-l-min-g-1-2-vbcd-1-2-de-fl-v0434/#respond</comments>
		
		<dc:creator><![CDATA[theplanmaster]]></dc:creator>
		<pubDate>Thu, 30 Jun 2022 06:49:33 +0000</pubDate>
				<guid isPermaLink="false">https://ziyacorp.com/product/double-overcenter-valve-vbcd-de-fl-60-l-min-g-1-2-vbcd-1-2-de-fl-v0434/</guid>

					<description><![CDATA[Overcenter valves are used where there is vital importance in the system. VBCD DE FL series are used to control actuator’s movement and block in both directions. Pressure is adjustable and sensitive. They can be used on crane booms and can easily mounted on cylinder with flanged ports. <div class="vc_row wpb_row row"><div class="vc_column_container col-md-12"><div class="wpb_wrapper vc_column-inner"><div class="vc_btn3-container vc_btn3-inline"><a class="vc_general vc_btn3 vc_btn3-size-md vc_btn3-shape-rounded vc_btn3-style-outline wpb_custom_4eba9bcc8f6c36e45e1d476fc3d9024c vc_btn3-icon-left vc_btn3-color-warning btn" href="https://ziyacorp.com/ziyacorpimages/inline-valves/overcenter-valve/o-vbcd-1-2-de-fl/vbcd-de-fl.pdf"><i class="vc_btn3-icon far fa-file-pdf"></i> Click for product document</a></div></div></div></div>]]></description>
										<content:encoded><![CDATA[<p>DOUBLE OVERCENTER VALVE<br />VBCD 1/2 DE FL &#8211; V0434<br />Overcenter valves have great importance in hydraulic systems and have following features:<br />Load holding: The overcenter valve prevents the movement of a load when the directional valve is in the neutral position, permitting the use of open center directional valves and negating leakage past the spool of closed center directional valves.<br />Load holding:<br />Load control: The overcenter valve prevents the actuator running ahead of the pump due to the load-induced energy, thereby eliminating cavitation in the actuator and loss of control.<br />Load control:<br />Load safety: In the case of hose failure, an overcenter valve mounted onto or into a cylinder will prevent uncontrolled movement of the load. When a cylinder is used in a boom, as in a crane, then hose failure protection is vital as the loss of load control could cause damage to people or property.<br />Load safety:<br />These valves are used where there is vital importance in the system.<br />VBCD DE FL series overcenter valves are used to control actuator’s movement and block in both directions. Pressure is adjustable and sensitive. They can be used on crane booms. Standard pressure setting is 320 bar.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://ziyacorp.com/product/double-overcenter-valve-vbcd-de-fl-60-l-min-g-1-2-vbcd-1-2-de-fl-v0434/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Double overcenter valve, VBCD DE FL , 40 L/min, G 3/8&#8243; , VBCD 3/8 DE FL V0424</title>
		<link>https://ziyacorp.com/product/double-overcenter-valve-vbcd-de-fl-40-l-min-g-3-8-vbcd-3-8-de-fl-v0424/</link>
					<comments>https://ziyacorp.com/product/double-overcenter-valve-vbcd-de-fl-40-l-min-g-3-8-vbcd-3-8-de-fl-v0424/#respond</comments>
		
		<dc:creator><![CDATA[theplanmaster]]></dc:creator>
		<pubDate>Thu, 30 Jun 2022 06:49:31 +0000</pubDate>
				<guid isPermaLink="false">https://ziyacorp.com/product/double-overcenter-valve-vbcd-de-fl-40-l-min-g-3-8-vbcd-3-8-de-fl-v0424/</guid>

					<description><![CDATA[Overcenter valves are used where there is vital importance in the system. VBCD DE FL series are used to control actuator’s movement and block in both directions. Pressure is adjustable and sensitive. They can be used on crane booms and can easily mounted on cylinder with flanged ports. <div class="vc_row wpb_row row"><div class="vc_column_container col-md-12"><div class="wpb_wrapper vc_column-inner"><div class="vc_btn3-container vc_btn3-inline"><a class="vc_general vc_btn3 vc_btn3-size-md vc_btn3-shape-rounded vc_btn3-style-outline wpb_custom_4eba9bcc8f6c36e45e1d476fc3d9024c vc_btn3-icon-left vc_btn3-color-warning btn" href="https://ziyacorp.com/ziyacorpimages/inline-valves/overcenter-valve/o-vbcd-3-8-de-fl/vbcd-de-fl.pdf"><i class="vc_btn3-icon far fa-file-pdf"></i> Click for product document</a></div></div></div></div>]]></description>
										<content:encoded><![CDATA[<p>DOUBLE OVERCENTER VALVE<br />VBCD 3/8 DE FL &#8211; V0424<br />Overcenter valves have great importance in hydraulic systems and have following features:<br />Load holding: The overcenter valve prevents the movement of a load when the directional valve is in the neutral position, permitting the use of open center directional valves and negating leakage past the spool of closed center directional valves.<br />Load holding:<br />Load control: The overcenter valve prevents the actuator running ahead of the pump due to the load-induced energy, thereby eliminating cavitation in the actuator and loss of control.<br />Load control:<br />Load safety: In the case of hose failure, an overcenter valve mounted onto or into a cylinder will prevent uncontrolled movement of the load. When a cylinder is used in a boom, as in a crane, then hose failure protection is vital as the loss of load control could cause damage to people or property.<br />Load safety:<br />These valves are used where there is vital importance in the system.<br />VBCD DE FL series overcenter valves are used to control actuator’s movement and block in both directions. Pressure is adjustable and sensitive. They can be used on crane booms. Standard pressure setting is 320 bar.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://ziyacorp.com/product/double-overcenter-valve-vbcd-de-fl-40-l-min-g-3-8-vbcd-3-8-de-fl-v0424/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Double overcenter valve, VBCD DE , 50 L/min, G 1/2&#8243; , VBCD 1/2 DE V0430</title>
		<link>https://ziyacorp.com/product/double-overcenter-valve-vbcd-de-50-l-min-g-1-2-vbcd-1-2-de-v0430/</link>
					<comments>https://ziyacorp.com/product/double-overcenter-valve-vbcd-de-50-l-min-g-1-2-vbcd-1-2-de-v0430/#respond</comments>
		
		<dc:creator><![CDATA[theplanmaster]]></dc:creator>
		<pubDate>Thu, 30 Jun 2022 06:49:30 +0000</pubDate>
				<guid isPermaLink="false">https://ziyacorp.com/product/double-overcenter-valve-vbcd-de-50-l-min-g-1-2-vbcd-1-2-de-v0430/</guid>

					<description><![CDATA[Overcenter valves are used where there is vital importance in the system. VBCD DE series are used to control actuator’s movement and block in both directions. Pressure is adjustable and sensitive. They can be used on crane booms. <div class="vc_row wpb_row row"><div class="vc_column_container col-md-12"><div class="wpb_wrapper vc_column-inner"><div class="vc_btn3-container vc_btn3-inline"><a class="vc_general vc_btn3 vc_btn3-size-md vc_btn3-shape-rounded vc_btn3-style-outline wpb_custom_4eba9bcc8f6c36e45e1d476fc3d9024c vc_btn3-icon-left vc_btn3-color-warning btn" href="https://ziyacorp.com/ziyacorpimages/inline-valves/overcenter-valve/o-vbcd-1-2-de/vbcd-de.pdf"><i class="vc_btn3-icon far fa-file-pdf"></i> Click for product document</a></div></div></div></div>]]></description>
										<content:encoded><![CDATA[<p>DOUBLE OVERCENTER VALVE<br />VBCD 1/2 DE &#8211; V0430<br />Overcenter valves have great importance in hydraulic systems and have following features:<br />Load holding: The overcenter valve prevents the movement of a load when the directional valve is in the neutral position, permitting the use of open center directional valves and negating leakage past the spool of closed center directional valves.<br />Load holding:<br />Load control: The overcenter valve prevents the actuator running ahead of the pump due to the load-induced energy, thereby eliminating cavitation in the actuator and loss of control.<br />Load control:<br />Load safety: In the case of hose failure, an overcenter valve mounted onto or into a cylinder will prevent uncontrolled movement of the load. When a cylinder is used in a boom, as in a crane, then hose failure protection is vital as the loss of load control could cause damage to people or property.<br />Load safety:<br />These valves are used where there is vital importance in the system.<br />VBCD DE series overcenter valves are used to control actuator’s movement and block in both directions. Pressure is adjustable and sensitive. They can be used on crane booms. Standard pressure setting is 320 bar.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://ziyacorp.com/product/double-overcenter-valve-vbcd-de-50-l-min-g-1-2-vbcd-1-2-de-v0430/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Double overcenter valve, VBCD DE , 105 L/min, G 3/4&#8243; , VBCD 3/4 DE V0431</title>
		<link>https://ziyacorp.com/product/double-overcenter-valve-vbcd-de-105-l-min-g-3-4-vbcd-3-4-de-v0431/</link>
					<comments>https://ziyacorp.com/product/double-overcenter-valve-vbcd-de-105-l-min-g-3-4-vbcd-3-4-de-v0431/#respond</comments>
		
		<dc:creator><![CDATA[theplanmaster]]></dc:creator>
		<pubDate>Thu, 30 Jun 2022 06:49:30 +0000</pubDate>
				<guid isPermaLink="false">https://ziyacorp.com/product/double-overcenter-valve-vbcd-de-105-l-min-g-3-4-vbcd-3-4-de-v0431/</guid>

					<description><![CDATA[Overcenter valves are used where there is vital importance in the system. VBCD DE series are used to control actuator’s movement and block in both directions. Pressure is adjustable and sensitive. They can be used on crane booms. <div class="vc_row wpb_row row"><div class="vc_column_container col-md-12"><div class="wpb_wrapper vc_column-inner"><div class="vc_btn3-container vc_btn3-inline"><a class="vc_general vc_btn3 vc_btn3-size-md vc_btn3-shape-rounded vc_btn3-style-outline wpb_custom_4eba9bcc8f6c36e45e1d476fc3d9024c vc_btn3-icon-left vc_btn3-color-warning btn" href="https://ziyacorp.com/ziyacorpimages/inline-valves/overcenter-valve/o-vbcd-3-4-de/vbcd-de.pdf"><i class="vc_btn3-icon far fa-file-pdf"></i> Click for product document</a></div></div></div></div>]]></description>
										<content:encoded><![CDATA[<p>DOUBLE OVERCENTER VALVE<br />VBCD 3/4 DE &#8211; V0431<br />Overcenter valves have great importance in hydraulic systems and have following features:<br />Load holding: The overcenter valve prevents the movement of a load when the directional valve is in the neutral position, permitting the use of open center directional valves and negating leakage past the spool of closed center directional valves.<br />Load holding:<br />Load control: The overcenter valve prevents the actuator running ahead of the pump due to the load-induced energy, thereby eliminating cavitation in the actuator and loss of control.<br />Load control:<br />Load safety: In the case of hose failure, an overcenter valve mounted onto or into a cylinder will prevent uncontrolled movement of the load. When a cylinder is used in a boom, as in a crane, then hose failure protection is vital as the loss of load control could cause damage to people or property.<br />Load safety:<br />These valves are used where there is vital importance in the system.<br />VBCD DE series overcenter valves are used to control actuator’s movement and block in both directions. Pressure is adjustable and sensitive. They can be used on crane booms. Standard pressure setting is 320 bar.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://ziyacorp.com/product/double-overcenter-valve-vbcd-de-105-l-min-g-3-4-vbcd-3-4-de-v0431/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Double overcenter valve, VBCD DE , 35 L/min, G 3/8&#8243; , VBCD 3/8 DE V0420</title>
		<link>https://ziyacorp.com/product/double-overcenter-valve-vbcd-de-35-l-min-g-3-8-vbcd-3-8-de-v0420/</link>
					<comments>https://ziyacorp.com/product/double-overcenter-valve-vbcd-de-35-l-min-g-3-8-vbcd-3-8-de-v0420/#respond</comments>
		
		<dc:creator><![CDATA[theplanmaster]]></dc:creator>
		<pubDate>Thu, 30 Jun 2022 06:49:29 +0000</pubDate>
				<guid isPermaLink="false">https://ziyacorp.com/product/double-overcenter-valve-vbcd-de-35-l-min-g-3-8-vbcd-3-8-de-v0420/</guid>

					<description><![CDATA[Overcenter valves are used where there is vital importance in the system. VBCD DE series are used to control actuator’s movement and block in both directions. Pressure is adjustable and sensitive. They can be used on crane booms. <div class="vc_row wpb_row row"><div class="vc_column_container col-md-12"><div class="wpb_wrapper vc_column-inner"><div class="vc_btn3-container vc_btn3-inline"><a class="vc_general vc_btn3 vc_btn3-size-md vc_btn3-shape-rounded vc_btn3-style-outline wpb_custom_4eba9bcc8f6c36e45e1d476fc3d9024c vc_btn3-icon-left vc_btn3-color-warning btn" href="https://ziyacorp.com/ziyacorpimages/inline-valves/overcenter-valve/o-vbcd-3-8-de/vbcd-de.pdf"><i class="vc_btn3-icon far fa-file-pdf"></i> Click for product document</a></div></div></div></div>]]></description>
										<content:encoded><![CDATA[<p>DOUBLE OVERCENTER VALVE<br />VBCD 3/8 DE &#8211; V0420<br />Overcenter valves have great importance in hydraulic systems and have following features:<br />Load holding: The overcenter valve prevents the movement of a load when the directional valve is in the neutral position, permitting the use of open center directional valves and negating leakage past the spool of closed center directional valves.<br />Load holding:<br />Load control: The overcenter valve prevents the actuator running ahead of the pump due to the load-induced energy, thereby eliminating cavitation in the actuator and loss of control.<br />Load control:<br />Load safety: In the case of hose failure, an overcenter valve mounted onto or into a cylinder will prevent uncontrolled movement of the load. When a cylinder is used in a boom, as in a crane, then hose failure protection is vital as the loss of load control could cause damage to people or property.<br />Load safety:<br />These valves are used where there is vital importance in the system.<br />VBCD DE series overcenter valves are used to control actuator’s movement and block in both directions. Pressure is adjustable and sensitive. They can be used on crane booms. Standard pressure setting is 320 bar.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://ziyacorp.com/product/double-overcenter-valve-vbcd-de-35-l-min-g-3-8-vbcd-3-8-de-v0420/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
